Model Thickness

On the Model Thickness tab of the Extrapolate Reference Seam form, the location of the Reference Seam can be modelled for holes that do not intersect it (using thickness information from surrounding holes).

Drillhole Database

Double-click (F3) to select the Drillhole Database (DHDB) that contains the interval data you will use to model the ply thickness, based on the holes that surround the reference seam.

Filter

Select the check box and set a filter if you want to limit the information that is processed from the Drillhole database .

The following parameters define a data search ellipse that will be used to calculate an appropriate ply thickness:

IDW inverse power

The weighting given to each point that falls in the search ellipse is inversely proportional to its distance from the centre raised to the value entered in IDW Inverse power.

A fixed sized grid is created using IDW with a huge search radius that includes all input points. After that the rough IDW grid is used as an input into a minimum curvature spline.

Search radius

The Search shape, defined by the number of Sectors you enter (below), determines the Search radius value you need to specify:

  • When the Search shape is CIRCLE, enter the radius of the data search circle in X axis units.
  • When the Search shape is ELLIPSE, enter the radius of the search ellipse in the X and Y directions.

In general, a good starting point is to make the radius about 1.5 to 2 times the grid spacing.

Sectors

This number defines how many parts the search shape will be divided into for the data search. The maximum number of points is multiplied by the number of sectors to determine how many data points can be used within the overall search shape.

For example, if you choose FOUR sectors, the search shape is a circle, and the maximum number of points is 15, then the nearest 15 data points in each quadrant will be used, totalling 60 points.

Max points per sector

The maximum number of points to be used in the estimation of a block value. The maximum allowable value is 150. When more than one sector is defined, each sector can independently use up to the maximum number of points. (e.g. 150 pts x 4 sectors = 600 pts).

If more than the maximum number of points is found within a sector, the closest points are used.

In Hole Seam Thickness

Seam thickness is modelled based on surrounding holes. There are options to insert either a zero thickness or a modelled thickness. The default action can be overridden, for specific holes. This is done by adding a field to the collar file that contains ‘1’ for any hole where seam thickness will be opposite to the default action. This field must be selected as an Attribute field in the Drillhole Database (on the Collar Attributes tab).

Naming

Output